Middle Atlantic rack WMRK

Multi-Vendor Server Enclosure


Middle Atlantic rack WMRK

Product SKU: WMRK Series

Spec Sheet
Spec Sheet

Features:
  • Standard front and rear adjustable cage nut style rail with Z-rail adaptors to accommodate most server-slide kits
  • UL Listed in the US and Canada
  • Fully welded construction provides:
    • Static load capacity: 10,000 lbs.
    • UL Listed load capacity: 2,500 lbs.
    • Seismic Certified load capacity: 1,090 lbs.
  • Seismic certified to the following codes and standards: 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010 Edition) and the 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity – Zone 4 or Seismic Design Category (SDC) "D". These are designed for Mission Critical and/or High-Importance Installations in locations with the highest level of seismicity and top floor or rooftop installations including those within UBC and CBC Essential facilities or IBC, ASCE 7, and NFPA 5000 Seismic Use Group III facilities. For all codes, the Importance factor (Ip) is 1.5. Seismic Certified load capacity of 1,090 lbs. when used with WMRK-Z4 seismic floor anchor brackets.
  • 24" overall width optimized for use on raised floors
  • Z-rail adaptors accommodates most server-slide kits
  • Configured for passive thermal management
  • Designed to allow fully integrated racks to be ganged
  • Removable split bottom rear panel allows cable bundles to be easily passed over or under the WMRK's key-locking split rear doors (standard on configured racks only)
  • Rack top includes five integral gland grommeted 4" cable pass-through (48" depth includes seven cable pass-throughs)
  • Stud in base of rack facilitates the proper grounding and bonding of electronic equipment, as per NEBS and NEC standards
  • Configured models include:
    - 70% vented locking front door
    - 79% vented locking split rear door
    - 20 amp power strip (20 outlets for 42 space models; 10 outlets for 24 space models)
    - Face mounted temperature monitoring module with local and remote notification
    - 42 space model shall additionally include 3-1/4" width vertical lacing strip
  • Non-configured models do not include a rear door


To order this item, please call 877-945-0550, fax 604-944-8894 or request a quote via the Request a Quote button below.

Vancouver Security Systems

 

     
Middle Atlantic rack WMRK
Features:
  • Standard front and rear adjustable cage nut style rail with Z-rail adaptors to accommodate most server-slide kits
  • UL Listed in the US and Canada
  • Fully welded construction provides:
    • Static load capacity: 10,000 lbs.
    • UL Listed load capacity: 2,500 lbs.
    • Seismic Certified load capacity: 1,090 lbs.
  • Seismic certified to the following codes and standards: 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010 Edition) and the 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity – Zone 4 or Seismic Design Category (SDC) "D". These are designed for Mission Critical and/or High-Importance Installations in locations with the highest level of seismicity and top floor or rooftop installations including those within UBC and CBC Essential facilities or IBC, ASCE 7, and NFPA 5000 Seismic Use Group III facilities. For all codes, the Importance factor (Ip) is 1.5. Seismic Certified load capacity of 1,090 lbs. when used with WMRK-Z4 seismic floor anchor brackets.
  • 24" overall width optimized for use on raised floors
  • Z-rail adaptors accommodates most server-slide kits
  • Configured for passive thermal management
  • Designed to allow fully integrated racks to be ganged
  • Removable split bottom rear panel allows cable bundles to be easily passed over or under the WMRK's key-locking split rear doors (standard on configured racks only)
  • Rack top includes five integral gland grommeted 4" cable pass-through (48" depth includes seven cable pass-throughs)
  • Stud in base of rack facilitates the proper grounding and bonding of electronic equipment, as per NEBS and NEC standards
  • Configured models include:
    - 70% vented locking front door
    - 79% vented locking split rear door
    - 20 amp power strip (20 outlets for 42 space models; 10 outlets for 24 space models)
    - Face mounted temperature monitoring module with local and remote notification
    - 42 space model shall additionally include 3-1/4" width vertical lacing strip
  • Non-configured models do not include a rear door
Product ID: 1244